03 / MEASURE WHAT MATTERS
Go beyond a feature checklist.
Select a KPI to explore the question, the measure, and the improvement it demands.
18 measures across 3 dimensions
Clinical / Artifact rejectionPriority gap
Are we calling noise an arrhythmia?
THE MEASURE
False arrhythmias per noisy hour; true beats wrongly excluded; usable signal coverage.
OUR NEXT MOVE
Add a quality timeline for each lead. Preserve raw samples and make every exclusion reversible.
What good looks like
Reduce false alarms without increasing missed events or concealing excluded signal.
Same metric. Same denominator. Same context. Compare beat accuracy with beat accuracy, episode detection with episode detection, and reviewed reports with reviewed reports. Always disclose the reference method, cohort and confidence interval.
04 / AN HONEST BASELINE
Our evidence, in the open.
PUBLIC DEVELOPMENT RECORD · LTAFDB 03
The current priority is classification reliability. These results are from one 24 h 16 min public recording. They do not establish performance across patients or independent clinical validation.
Inspect the denominator
A percentage is only useful when you know what was counted.
40.3%PAC precision2,046 / 5,075 beats
2,046 true positives3,029 false positives
False positives3,029
Missed reference beats167
False positives / hour124.8
Baseline → current engine: unchanged on this recording. Zero-error detection has not been achieved.
View both classes and evaluation context
Beat classification against the public reference annotations
Class
True positives
False positives
False negatives
Precision
Sensitivity
PAC
2,046
3,029
167
40.3%
92.5%
PVC
32
966
64
3.2%
33.3%
Overall QRS detection: 83,296 detections versus 80,957 reference beats; 571 missed and 2,910 extra detections. Classification errors and detection errors are different measures.
Source: repository validation snapshot, 4 November 2026. Automated predictions, before clinical adjudication. No confidence interval or multi-patient generalization estimate is provided by this single-record snapshot.
FOUNDATION RELEASE · MEASURED PROGRESS
Durable review. A stricter accuracy gate.
Browser-local clinical recovery and JSON backups shipped. Both accuracy candidates were rejected; the deployed engine is unchanged.
31 registered development cases: 30 excerpts and controlled corruptions, plus the complete LTAFDB03 recording. Each excerpt baseline was run twice in Chromium with identical results. These exposed, overlapping cases are not independent clinical validation.
Rejected · Not promoted — signal-quality experiment. Deterministic Python decision replay on identical browser detections and verified native samples; no new model inference.
The promotion gate requires fewer PAC/PVC false positives overall, no additional PAC or PVC misses, and no false-positive regression for either class on any registered case. Added excluded time or missed detections also blocks promotion.
Case-weighted development aggregate · beat classification
Engine / class
TP
FP
FN
Precision
Sensitivity
FP / source hour
Burden error (pp)
Baseline · PAC
2,133
3,076
269
40.95%
88.80%
124.70
3.39
Candidate · PAC
2,129
3,044
273
41.16%
88.63%
123.41
3.34
Baseline · PVC
226
1,043
101
17.81%
69.11%
42.28
1.14
Candidate · PVC
226
1,043
101
17.81%
69.11%
42.28
1.14
FN includes missed detections, incorrect classes and abstained true ectopy. Burden error uses the same known-reference beat denominator for both methods. Rates use source hours; clinically analyzable hours remain unassessed. Aggregate hours count overlapping cases separately.
Detection, uncertainty and episode correspondence are separate measures
Measure
Baseline
Candidate
Matched QRS detections
82303
82303
Extra QRS detections
2968
2968
Missed reference QRS
596
596
Unknown classifications
300
336
Technically excluded seconds
0.005556
0.005556
Ectopic run candidates
212
212
Matched reference runs
11
11
Unmatched run candidates
201
201
Missed reference runs
11
11
Episode comparison covers maximal runs of at least three same-class ectopic beats under the registered overlap rule. It does not validate automatic SVT or VT diagnoses. ST analysis remains excluded.
Why this candidate was rejected (1 checks)
ltafdb03 PAC: additional misses
Historical implementation defects and remaining limits
Previously demonstrated DC-offset, dropout and alternate-channel defects are replayed separately using preserved engine 1.1 and 1.2 exports. Their aggregate PAC/PVC false positives were 4,058 → 4,061. That historical repair fails this release’s stricter gate and is not claimed as a new accuracy improvement.
All cases were previously exposed to development. MITDB repeated recordings 201/202 remain grouped. LTAFDB patient linkage and pretraining overlap are unverified. An untouched clinical cohort still needs evaluation.
19,304 source-linked error entries retain waveform coordinates, lead measurements and candidate uncertainty reasons. Noise, duplicate detection, T-wave detection and morphology disagreement remain review hypotheses; causal labels require waveform adjudication.
Active engine: native-heartkit/1.3.0 / heartkit-refinement-v2. Reviewer credentials remain locally entered typed attestations. Cloud accounts, synchronization and new automatic rhythm diagnoses are outside this release.
Models · what actually runs
Inside the Holter classifier.
HeartKit and refinement-v2 generate the current beat proposals. The newly tested classifiers and detectors are research candidates; they are not active in Holter.
Active in the browserheartKIT BEAT-3-EFF-SM+ heartkit-refinement-v2native-heartkit/1.3.0Active means shipped, not clinically validated.
The active native Holter path
Runs on this device · original ECG preserved
Select any stage to see its inputs, outputs and limits.
03 / heartKIT BEAT-3-EFF-SM
What does the waveform around this beat resemble?
The deployed EfficientNetV2 model scores a fully supported frame around each candidate beat, separately for each usable lead. It produces normal, PAC and PVC scores.
Input
A centered 5.12-second waveform frame for each usable lead.
Output
Three morphology scores per usable lead.
Illustration only · Shading represents waveform context, not a measured duration
Frames are resampled to 100 Hz, giving 512 samples, and normalized before TensorFlow Lite inference in the browser worker. A score is model output, not a clinically calibrated probability. Missing edge or gap context leaves the beat unclassified.
“Completed” can mean new inference or a verified saved analysis.
A matching browser cache or the prepared public Record 03 example can restore predictions after source, header, engine and model checks. “Completed · verified saved analysis” means those saved results were loaded. For a fresh run, use Reanalyze full recording in the recording workspace. Saved reviews require matching source and exact analysis evidence.
The research path
Offline experiments · no connection to live classification
Not active
Extra Trees + boosted trees
Three fitted classifiers use 107 morphology and timing features. Extra Trees led their validation objective, but added true ectopy misses.
Not active
xECG + a fitted beat head
The foundation model runs in the offline GPU environment. Two fitted heads were tested on five-minute MIT-BIH prefixes; both failed promotion.
Not active
FastNVG and other detectors
Five timing methods were compared separately. FastNVG led aggregate detection F1, but regressed on individual cases and missed more ectopic beats.
Why the live model stayed the same
Fewer false alarms can still mean more missed beats.
The selected xECG pilot head reduced false PAC proposals from 143 to 7. But on those same regression excerpts, it missed 4 of 15 reference PACs; the paired baseline missed 2 of 15. PVC false positives also rose from 29 to 33.
Five-minute development prefixes, not full-Holter or independent clinical validation. This paired Python baseline is distinct from the browser acceptance cohort.
The same 15 reference PACs
Paired baseline2 missed
xECG pilot4 missed
Correct PAC proposal Missed or misclassified PAC
Promotion blocked · current engine retained
What must happen before a candidate becomes the live classifier?
Freeze a fair comparison. Register waveform identities, patient groups, model versions and matching rules before comparison. Previously exposed recordings remain development material.
Pass every accuracy condition. Fewer PAC/PVC false positives overall, no additional PAC/PVC misses and no per-class/per-record false-positive regression. Unknown beats, detection misses and excluded coverage stay visible.
Verify the browser implementation. Export and check numerical behavior, original-source handling and the full registered acceptance cases. An offline result alone does not activate a model.
Publish a new engine version. Ship its exact model assets and run identity, then verify production. Incompatible results cannot inherit an earlier review’s approvals.
None of the five new classifiers or five detector candidates passed its gate. Publishing their results changed the evidence page, not the model used for your Holter analysis.
MODEL SEARCH · MEASURED COMPARISONS
Five classifiers. Five detector candidates. No promotion.
Extra Trees led the native-feature validation objective. FastNVG led aggregate detection F1. Neither met every acceptance condition. The xECG beat-head pilot also failed.
The active engine remains native-heartkit/1.3.0 / heartkit-refinement-v2. These experiments use exposed development recordings. They do not establish independent clinical accuracy.
Records needing attention
Ranked within the selected experiment and cohort by additional PAC/PVC misses, then additional false positives. These are development errors, not clinical risk scores.
Recording
Additional misses
Additional false positives
Evidence
209
207
0
222
60
0
201
38
0
202
38
0
220
14
0
228
9
0
109
7
0
105
2
0
Beat classification
These selectors only change the results shown here. They do not switch the model used in the Holter workspace.
107 native morphology / RR features. Paired Python replay on identical independent detections, compared with refinement-v2. These baseline values are distinct from the deployed browser acceptance results above. xECG uses five-minute prefixes; the other classifier experiments use full recordings.
Rejected · Not promoted. 0 of 32 validation policies met the strict gate. Selected validation objective: 69.14%. Objectives from different cohorts are not a direct model ranking.
Class / method
TP
FP
FN
Precision
Sensitivity
FP / source hour
Burden error (pp)
PAC · Baseline
665
1,251
207
34.71%
76.26%
249.43
4.77
PAC · Candidate
344
134
528
71.97%
39.45%
26.72
-1.80
PVC · Baseline
649
474
12
57.79%
98.18%
94.51
2.11
PVC · Candidate
595
61
66
90.70%
90.02%
12.16
-0.02
Unknown classifications: 70 → 862. Detection misses: 44 → 44. Source hours: 5.02 → 5.02. No detections or source time are removed by these classifier candidates. Clinical analyzable duration and artifact rejection remain unassessed. Abstained true ectopy remains a miss. Burden error uses the shared known-reference denominator.
Why this cohort failed the gate
105 PVC: additional misses
109 PVC: additional misses
201 PAC: additional misses
201 PVC: additional misses
202 PAC: additional misses
202 PVC: additional misses
209 PAC: additional misses
220 PAC: additional misses
222 PAC: additional misses
228 PAC: additional misses
228 PVC: additional misses
The Extra Trees table uses the corrected float-comparison replay. One full-record normal/unknown decision changed; its PAC/PVC counts and rejection were unchanged. No browser inference weights were changed.
ECGFounder · measured beat-head pilot
Both frozen-encoder heads failed the promotion gate. Regression false positives decreased, but individual recordings gained missed PAC/PVC beats. The active classifier remains unchanged.
9,722 training beats; first five minutes per recording; MLII only; beat-centered ten-second windows. This tests transfer from a diagnosis encoder to beat classification on exposed development patients, not full-day or clinical performance.
Pilot runtime: 108.5 seconds. Peak PyTorch allocated GPU memory: 172.5 MiB, excluding driver and other process allocations. Frozen prediction replay: verified exactly.
Neither model passed this six-case pilot. Both returned valid JSON but selected zero-count or irrelevant facts. The optional local assistant remains experimental; it displays canonical comparison facts and cannot write reports or change analysis results.
CPU-only inference on Intel(R) Core(TM) 7 240H, Ollama 0.40.15, Q4_K_M checkpoints and a 2,048-token context. Cases cover nonzero, zero, empty, mixed counts, instruction conflict and unsupported diagnosis. This measures evidence selection, not ECG interpretation or clinical accuracy.
Model tag
Cases passed
Request latency range
Decision
qwen3:1.7b
2 / 6
0.23–2.22 s
Failed pilot
gemma3:1b
2 / 6
0.43–1.49 s
Failed pilot
Latency includes the response and runtime-status request. The first case for each model includes model loading. Six cases are too few to estimate reliability. No generated report drafting is enabled.
All five detector candidates failed the per-case gate. Every reference beat remains in scoring, including unavailable source intervals. Detectors use the first recorded channel; the consensus experiment intersects the first two channels. Every run was repeated with identical detections. No episode or classification improvement follows from detection scores alone.
Detector gate failures and source availability
Unavailable intervals and reasons are included per channel in the downloadable results. Missing samples are never interpolated. The source waveform is preserved.
Reviewed against official source code and model cards on 2026-11-04. A diagnosis model needs a fitted beat head before it can make PAC/PVC beat proposals. Original ECG, clinician review and ST exclusion remain in place.
Next experiments · local feasibility
RTX 5060 Laptop GPU, 8151 MiB VRAM. Unmeasured runtime and memory values are not estimates of demonstrated performance.
ECGFounder single-lead beat-head experiment — Measured; both beat heads rejected
Frozen representation plus fitted PAC/PVC head. Pinned single-lead encoder with reproduced filtering, baseline subtraction and z-score preprocessing; 9722 training beats, MLII ten-second windows, five-minute prefixes. C=0.1 and C=1 heads both failed the existing gates. Frozen prediction replay matched exactly.
Next step: Classify existing source-linked errors by detection, classification, signal quality and lead mismatch. Register one focused experiment with separate development and evaluation recordings, fixed metrics and promotion criteria before running it. Preserve the failed heads and frozen artifacts; no promotion or full-day accuracy claim.
Terms: Repository MIT; preserve checkpoint and source-data terms.
Primary sourceECG-R1 — Not run; local memory feasibility unresolved
Direct signal/image interpretation research. Released 8B model supports signal and image interpretation. Eight billion BF16 parameters alone require about 16 GB decimal, exceeding this GPU before encoder and runtime overhead. Quantized/offloaded performance has not been measured.
Next step: Research shortlist only; no report integration. The upstream waveform/image interpretation project reports unreliable generated interpretations across evaluated models. First resolve preprocessing and local feasibility, then register independent verification with separate development and evaluation cases. Keep cloud evaluation scripts disabled.
Terms: Checkpoint and dependency terms need separate verification before integration.
Primary sourceECG-Chat — Not run; reproducibility prerequisites unresolved
Direct ECG report generation research. Official repository links ECG-CoCa and ECG-Chat checkpoints through Google Drive. Report-generation evaluation and RAG code are described as forthcoming.
Next step: Resolve immutable checkpoint identities, input contract and evaluation implementation before comparing generated reports.
Terms: No deployment rights inferred; verify all checkpoint and dependency terms.
Primary sourceLocal evidence-grounded assistant — Measured; both models failed the six-case pilot
Select supplied PAC/PVC comparison evidence. Qwen3 1.7B and Gemma 3 1B each passed 2 of 6 synthetic cases on isolated Ollama 0.40.15 CPU inference. Both selected zero-count or irrelevant facts despite valid JSON. Original evidence wording and counts remain application-controlled.
Next step: Use deterministic nonzero PAC/PVC error summaries by default. Keep the optional selector experimental and preserve its 2/6 results. Any revised selector needs separate development and evaluation cases; report drafting remains disabled.
Terms: Depends on the selected checkpoint.
Primary sourcexECG + fitted beat head — Implemented offline; runtime and patient-separated pilot measured
Heartbeat representation and PAC/PVC classification. Foundation-model research priority because patch-level features support heartbeat heads. The local linear-probe results determine eligibility, not the paper's aggregate rankings.
57,021,472 parameters; 228 MB safetensors; 100 Hz, canonical 12-lead slots, known missing leads zero. Generic ECG lead labels rejected. Base checkpoint has no fitted PAC/PVC head. Pretraining overlap unknown.
Published terms: Model card and repository MIT; upstream README separately says research, not clinical care or commercial use. No deployment license conclusion inferred.
Extra Trees + morphology/RR context — Implemented, fitted, exported and evaluated; rejected
PAC/PVC/unknown classification. Best validation objective among the three 107-feature candidates in this experiment. Its reduced PAC sensitivity blocks promotion.
Exposed patients, Python replay and no browser conformance. Fewer aggregate false positives do not compensate for additional misses.
Published terms: Local model fitted using scikit-learn BSD-3-Clause implementation; source-dataset conditions remain applicable.
ECG representation and diagnosis transfer. Useful second representation baseline after task-specific head training, rather than a direct PAC/PVC replacement.
90.9M parameters, wav2vec 2.0, fairseq_signals runtime. Released signal-level outputs cannot be treated as beat labels.
Published terms: Repository MIT; checkpoint and dataset terms must be retained separately.
Dual-channel CNN-LSTM PAC/PVC — Code inspected; not loaded or redistributed
NSR/PAC/PVC segment classification. Resolve the exact segment/sample-rate contract, label-independent lead selection and redistribution terms before a fair comparison.
Published helper uses whole-model pickle loading and label-dependent lead choices for some datasets. Those choices cannot enter independent inference.
Published terms: No explicit LICENSE file found in the inspected repository revision.
FastNVG, NeuroKit, XQRS and SleepECG — Implemented and measured separately on 31 registered cases
QRS detection. FastNVG has the best aggregate detection F1 in this local comparison; none passes the per-record and ectopy-miss gate. Retain the deployed detector.
Detection is not classification. Two-lead consensus performed poorly when the second lead was unreliable. Exposed overlapping cases are not independent validation.
Published terms: Use each upstream package's license; pinned installed versions are recorded in the detector registration.
Signal-quality evidence and denoising — Conservative quality candidates measured previously; learned denoising not activated
Technical quality and artifact review. Use detector disagreement and source descriptors to prioritize review. Evaluate quality labels separately before any automatic exclusion.
Detector disagreement does not establish noise. Denoising can change morphology, so preserve original samples and evaluate any transformed signal separately. No clinical quality ground truth is available here.
Published terms: Check individual implementations and model cards before integration.
Classify existing source-linked disagreements by detection, classification, signal quality, and lead mismatch. Keep ambiguous and unassessable cases explicit. Then register one focused experiment with separate development and evaluation recordings, fixed metrics, and promotion criteria before running it.
ECG-R1 remains on the research shortlist
The upstream project targets waveform and image interpretation and reports unreliable generated interpretations across evaluated models. Independent verification is required. It is not integrated into analysis or reports. Official ECG-R1 repository.
ALREADY IN PLACE
A foundation for traceable review.
All recorded leads, reversible beat review, source-linked evidence, separate reviewed rhythm entries, consistent report counts, browser-local clinical recovery, validated JSON backups, and a typed attestation invalidated by edits.
WHAT STILL NEEDS WORK
Accuracy and independent validation.
All registered classifier and detector candidates failed the strict promotion gate. Account storage remains unavailable on Vercel. Automatic AF, conduction and QT diagnosis is not established by these results.
05 / FROM EVIDENCE TO ACTION
Build in the right order.
Delivery status follows the release evidence. Each step has a concrete acceptance condition.
01
Establish the measurement baseline
Foundation shipped
Registered 31 exposed development cases, patient grouping, source/model fingerprints, fixed matching rules and two candidate configurations before comparison. An untouched clinical cohort remains a gap.
DELIVERY EVIDENCE
The reproducible comparison publishes separate detection, classification and run metrics, abstentions, excluded coverage and per-case strict gates. Thirty browser excerpt baselines reproduced exactly on a second run.
02
Repair artifact and beat classification
Candidates rejected
Tested source-quality and multilead rules, three learned morphology classifiers, two fitted xECG beat heads and five QRS detector candidates. All failed their strict promotion gates; full and short-prefix experiments remain separate.
DELIVERY EVIDENCE
The existing engine is retained. Published failures and a source-linked error inventory preserve unknown classifications, missed events and technical exclusions; causal adjudication remains unresolved.
03
Make review durable
Browser-local shipped
Clinical forms, episode boundaries, QT measurements, beat-review history, reviewer details and typed attestations now persist with source/run checks and revision-checked saves. JSON backup restoration requires explicit replacement.
DELIVERY EVIDENCE
Migration, reload, result eviction, competing tabs, failed/interrupted saves and backup validation pass regression tests. Restored reports reproduce counts, boundaries, narrative and digest. Authenticated identity and cross-device sync remain outside this release.
04
Reduce clinician effort
Workflow
Add morphology groups, beat superposition, RR plots, a quality timeline and reversible batch correction.
DONE WHEN
Clinicians complete representative reviews faster without worse missed-event or amendment rates.
05
Validate rhythm-specific assistance
Clinical depth
Develop or evaluate licensed delineation and rhythm analysis. Validate SVT, sinus tachycardia, AF/flutter, VT and AV block separately.
DONE WHEN
Each supported rhythm has a defined intended use, measured performance and an explicit uncertainty path.
06
Complete the clinic workflow
Delivery
Add symptom correlation, printable PDF reports, amendments, institution templates and device integrations chosen with pilot clinics.
DONE WHEN
A clinic can import, review, sign, deliver and retrieve a report. EU and US readiness are assessed separately.
TWO MARKETS, EXPLICIT REQUIREMENTS
Europe and the United States.
Keep intended use, supported devices and regulatory readiness separate for each market. Software tests and a successful deployment are not clinical validation.